- Gas Heater, Carbon Dioxide, Electric
- Gas Manifold, Carbon Dioxide
- Gas Purity Tester, Zahm (see Carbon Dioxide Purity Tester, Zahm)
- Gas Regulator, Compact, High Accuracy
- Gas Regulator, Economical
- Gas Regulator, Heavy Duty
- Gas Regulator, High Purity
- Gas Regulator, Medium Duty
- Gas Volume Chart (see Carbonation Calculator, Manual)
- Gauge Adapter, Test, Quick Disconnect
- Gauge Adapter, Test, Zero Pressure
- Gauge Tester, Bench, Dead Weight
- Gauge Tester, Bench, Dead Weight, Pneumatic Adapter
- Gauge Tester, Portable, Mechanical, (Liquid Filled)
- Gauge Tester, Portable, Pneumatic, Digital and Mechanical
- Gauge Tester, Vacuum
- Gauge, Pressure, Electronic With Digital Meter
- Gauge, Pressure, Mechanical
- Gauge, Pressure, Test (High Accuracy)
- Gauge, Vacuum, Electronic With Digital Meter
- Gauge, Vacuum, Mechanical
- Gauge, Wall Thickness, Electronic
- Glassware Rack (see Rack, Glassware, Draining, Drying)
- Glassware, Laboratory, Certified, Custom
- Glycerine, Food Grade
- Graduate, Cone Shape, Pharmaceutical Type
- Handle, Broom (see Broom Handle)
- Handle, Brush, Tank (see Tank Brush Handle)
- Hardness Test Kit (see Test Kit, Hardness, Titration)
- Headspace Elimination, Cone Assembly
- Heater, Gas (see Gas Heater, Carbon Dioxide, Electric)
- Hose, Tygon (see Tubing, Sanitary, Flexible, Tygon)
- Hydrometer Cylinder (see Cylinder, Hydrometer)
- Hydrometer Rack
- Hydrometer, Brewing, Balling, w/Thermometer, Certified
- Hydrometer, Brewing, Plato, w/Thermometer, Certified
- Hydrometer, Brewing, Proof, Tralles, w/Therm, Certified
- Hydrometer, Brewing, Proof, without Thermometer, Certified
- Hydrometer, Fructose, Certified, 42% and 55%, w/Mercury Thermometer
- Hydrometer, Fructose, Certified, 42% and 55%, w/Red Spirit Thermometer
- Hydrometer, Sucrose, Certified, w/Mercury Thermometer
- Hydrometer, Sucrose, Certified, w/Red Spirit Thermometer
- Hydrometer, Sucrose, Non-Certified, w/Mercury Thermometer
- Hydrometer, Sucrose, Non-Certified, w/Red Spirit Thermometer
- Hydrometer, Sucrose, Royal Crown, Certified, w/Mercury Thermometer
- Hydrometer, Sucrose, Royal Crown, Certified, w/Red Spirit Thermometer
- Hydrometer, Sucrose, Royal Crown, Non-Certified, w/Mercury Thermometer
- Hydrometer, Sucrose, Royal Crown, Non-Certified, w/Red Spirit Thermometer
-
Gas Heater, Carbon Dioxide, Electric |
Click on the picture for a larger view |
T-20-130 |
120 VAC |
T-20-127 |
220 VAC |
|
|
Provides uniform temperature and constant flow of gas. Prevents regulator freeze-up and resultant pressure fluctuation. Capacities available up to 1,000 lbs of carbon dioxide per 8 hour day. |
RETURN |
Gas Manifold, Carbon Dioxide |
Click on the picture for a larger view |
T-20-120 |
Wall mounted |
T-20-124 |
Self standing |
T-20-125 |
Heater |
T-20-128 |
Regulator |
T-20-122 |
18" Stainless Braided Pigtail |
|
|
• Gas Cylinders can be replaced without cutting off supply.
• Specify the number of cylinders and whether wall mounted or self standing, single bank, split bank with manual changeover or automatic changeover.
• Cylinders not included. |
RETURN |
Gas Regulator, Compact, High Accuracy |
|
T-20-110 |
3 - 150 psig outlet pressure range |
|
|
An excellent, high accuracy regulator for lab use, this compact unit is capable of inlet pressures up to 6,000 psig (415 bar) and provides secondary pressure ranges of 4 - 50, 4 - 150 and 4 - 250 psig (0.3 - 3.5, 0.3 - 10.3 and 0.3 - 17 bar). It is non-venting, has low operating handknob torque and is easy to maintain. Numerous porting options are available. It can be ordered in brass, aluminum and stainless steel. The unit listed is constructed of brass. Its inlet, outlet and gauge ports are 1/4"
FNPT. |
RETURN |
Gas
Regulator, Economical |
Click on the picture for a larger view |
T-20-105 |
Gas regulator, single stage, economical |
T-20-102 |
Spare Pressure Gauge, 400 psi |
T-20-104 |
Spare Pressure Gauge, 4000 psi |
|
|
• CGA-320 inlet and 5/8-18 RH outlet connection.
• Mamimum inlet pressure: 3000 psi.
• Maximum outlet pressure: 200 psi. |
RETURN |
Gas Regulator, Heavy Duty |
Click on the picture for a larger view |
T-20-100 |
Gas regulator, heavy duty, twin gauge |
T-20-102 |
Spare Pressure Gauge, 400 psi |
T-20-104 |
Spare Pressure Gauge, 4000 psi |
|
|
This twin gauge, brass precision regulator offers uninterrupted service for plant operations. Trouble free construction measures both incoming gas pressure and pressures going into carbonator. Complete with easy to read vertically mounted gauges. Heavy duty two stage manifold model with large 1-11 by 1/2" NPS inlet and outlet connections, delivers steady uniform pressure regardless of cylinder pressure.
• Maximum inlet pressure: 3000 psi.
• Maximum outlet pressure: 200 psi. |
RETURN |
Gas Regulator, High Purity |
Click on the picture for a larger view |
T-02-695 |
Ultra Pure Regulator |
|
|
For use primarily in the laboratory to maintain the purity of the gas. |
RETURN |
Gas Regulator, Medium Duty |
Click on the picture for a larger view |
T-20-103 |
Gas regulator, medium duty, brass |
T-20-101 |
Spare Pressure Gauge, 100 psi |
T-20-104 |
Spare Pressure Gauge, 4000 psi |
|
|
Two stage cylinder regulator maintains steady pressure while the cylinder is emptying.
• CGA-320 inlet and 5/8-18 RH outlet connection.
• Maximum inlet pressure: 3000 psi.
• Maximum outlet pressure: 80 psi. |
RETURN |
Gauge Adapter, Test, Quick Disconnect |
Click on the picture for a larger view |
|
|
The quick-disconnect adapter permits the easy checking and recalibration of pressure gauges and electronic transducers without their removal from the piercing device. It can be used with any Terriss bench-style piercing device or the Zahm D-T model. The adapter fits both the Portable Pressure Gauge Tester and the Dead Weight Tester and eliminates the danger of damaging either the pressure gauge or transducer while removing to recalibrate. |
RETURN |
Gauge Adapter, Test, Zero Pressure |
Click on the picture for a larger view |
|
|
This device provides a "zeroing" capability to the Dead Weight Tester so that gauges and pressure transducers can be properly calibrated. The standard fitting arrangement on the unit is for pressure transducer connector, T-02-715. |
RETURN |
Gauge Tester, Bench, Dead Weight |
Click on the picture for a larger view |
T-03-700 |
Unit, complete, 100 psi |
T-03-797 |
Unit, complete, 100 psi w/certification |
T-03-705 |
Unit, complete, 300 psi |
T-03-798 |
Unit, complete, 300 psi w/certification |
T-03-799 |
Certification only |
T-03-701 |
Leather cup washer |
T-03-702 |
Flat Leather Packing Washer |
T-03-703 |
Glycerine, Food Grade, 16 oz |
T-03-704 |
Tool kit with adapters |
T-03-706 |
Fiber gasket |
T-03-511 |
1/8" NPT brass adapter |
T-02-558 |
Dead Weight Pressure Trans. Adapter |
|
|
This unit provides precise and accurate primary calibration for pressure gauges and electronic transducers in 5 lb increments. Complete with tool kit and certified weights (1-5 lbs, 3-10 lbs and 3-20 lbs). The 300 psi unit includes four additional 50 lbs. weights. NIST traceable certificate available at extra cost. |
RETURN |
Gauge Tester, Bench, Dead Weight, Pneumatic Adapter |
Click on the picture for a larger view |
T-03-720 |
Pneumatic Adapter |
T-03-740 |
Piercing device adapter/thermo-well |
T-03-741 |
Piercing device adapter/piercing needle |
|
|
The Pneumatic Adapter (T-03-720) converts the Dead Weight Tester (T-03-700) to air without sacrificing any current pressure gauge calibration procedures or standards (as specified by the parent companies). By using air pressure (up to 100 lbs.) instead of oil, calibration can be accomplished easily and cleanly without taking the gauge off of the instrument. Calibration can be done remotely (that is, at a distance from the Dead Weight Tester.) Gauges may be connected directly to the Adapter as well.
How does the Pneumatic Adapter work?
The Pneumatic Adapter is connected to the pressure gauge port of the Dead Weight Tester through the oil reservoir (which is supplied with the unit). An inch of oil is pushed into the reservoir using the screw adjustment on the Dead Weight Tester. Any source gas may be used, including a hand pump. The pressure of the source gas should be set 20 lbs. higher then the highest pressure to be tested. Open the inlet valve when ready.
The Dead Weight Tester becomes in effect the "on-line"calibration gauge for the Pneumatic Adapter. A precision regulator permits the operator to choose a pressure setting which, once locked into place, supplies this pressure +/- .1 psi. (When the weights on the Dead Weight Tester are floating and stable, the correct air supply pressure has been found.) A precision gauge on the Adapter makes it easy to find the right pressure. Thus, the Pneumatic Adapter supplies a calibrated source of air pressure to the gauge to be tested.
The Piercing Device Adapters (T-03-740 and T-03-741) permit the operator to test both pressure gauges and electronic transducers without removing them from the beverage piercing device. The Piercing Device Adapter is connected to the Pneumatic Adapter by a length of tubing. The operator keeps the valve on the Piercing Device Adapter closed until ready to test. Then the pressure gauge is calibrated against the calibrated air source from thePneumatic Adapter. (For zero pressure, close the valve on the Piercing Device Adapter and open the snift valve on the piercing device.)
The schematic shows how the Pneumatic Adapter is set up. The tubing arrangement from the source gas to the PneumaticAdapter and from the Adapter to the piercing devices can be customized, depending on the physical layout of the laboratory.
|
RETURN |
Gauge Tester, Portable, Mechanical, (Liquid Filled) |
Click on the picture for a larger view |
T-03-707 |
Unit, complete, 100 psi |
T-03-710 |
Unit, complete, 300 psi |
T-03-058 |
Pressure gauge, 100 psi and 7 kg/cm2 (#22) |
T-03-609 |
Pressure gauge, 400 psi |
T-03-607 |
Neoprene "O" ring set |
|
|
Accuracy of pressure gauges can be quickly checked with this portable test kit. Screwed into the threaded port, gauge is put under pressure by turning the handle on the water-filled tester. The tested gauge requires recalibration when the reading differs from the master gauge. Stainless steel instrument comes packed in a padded carrying case, with needle puller, resetting tool and a screwdriver for recalibrating faulty gauges. Occasional recalibration of master gauge on a dead weight tester is necessary. |
RETURN |
Gauge Tester, Portable, Pneumatic, Digital and Mechanical |
Click on the picture for a larger view |
T-03-712 |
Unit, complete, 0 - 100 psi range digital gauge |
T-03-713 |
Unit, complete, 0 - 60 psi range mechanical gauge |
T-03-718 |
Gauge, digital, 100 psi, 0.1% accuracy FS, 2-1/2"
dia. face |
T-03-578 |
Gauge, mechanical, 60 psi, +/- 0.25 psi accuracy FS, 2-1/2"
dia. face |
|
|
Easy to use pneumatic gauge tester with a screw-style fine adjustment. Equipped with a digital gauge the unit has a resolution and accuracy of +/- 0.1 psi; with a mechanical test gauge +/- .25 psi.
For superior performance use in conjunction with the Terriss Electronic Pressure Gauge with Digital Meter (T-11-500). This unit is rugged, highly accurate and can be calibrated by the user against any physical standard like a dead weight tester. See
Gauge, Pressure, Electronic With Digital
Meter, Terriss for more information on this unit. |
RETURN |
Gauge Tester, Vacuum |
Click on the picture for a larger view |
T-03-750
|
Unit complete, 0 - 25 inches of mercury (mechanical
guage) |
T-03-755 |
Spare precision vacuum test gauge |
T-11-521 |
Digital vacuum meter, only |
T-02-817 |
Electronic vacuum gauge, only |
|
|
A unique light weight device for testing vacuum in ranges up to 25" of mercury. A 24" long hose with 1/4" adapter is supplied with the unit.
For more precision and a RS232 computer connection order this unit with a Digital Vacuum Gauge and Meter. |
RETURN |
Gauge, Pressure, Electronic With Digital Meter |
Click on the picture for a larger view |
T-11-500 |
Unit, complete |
T-11-501 |
Digitial meter |
T-02-815 |
Pressure transducer, 0 - 100 psi |
|
|
The Terriss Digital Vacuum Meter comes complete with electronic vacuum gauge and a power cord. The vacuum meter can be calibrated to any physical standard.
Features:
• Quick disconnect permits the vacuum gauge to be removed without tools (1/8th MNPT is standard. Other sizes are available. Please specify.)
• Range: 0 to 30 inches of mercury
• Accuracy: +/- 0.25% of full scale
• Ruggedly constructed and water resistant
• RS232 port for connection to a computer
• 120 VAC is standard. 220 VAC is available. Please specify.
• Special rack mounting kits are available. Please inquire.
Terriss offers custom meters manufactured to your specifications. Please inquire. |
RETURN |
Gauge, Pressure, Mechanical |
Click on the picture for a larger view |
T-03-035 |
Pressure gauge, 30 psi and 2 kg/cm2 |
T-03-117 |
Pressure gauge, 60 psi and 4 kg/cm2 |
T-03-058 |
Pressure gauge, 100 psi and 7 kg/cm2 (#22) |
|
|
Gauge Specifications
T-03-117: 0 - 60 psi in 1 psi increments with 2" dial, recalibration screw directly on face of dial, dual scale (psi and 0 - 4 kg/cm2), 2%-1%-2% accuracy.
T-03-058: 0 - 100 psi in 1 psi increments with 2 1/2" dial, recalibration screw directly on face of dial, dual scale (psi and 0 - 7 kg/cm2), 2%-1%-2% accuracy.
T-03-035: 0 - 30 psi in 1/2 psi increments with 2" dial, recalibration screw directly on face of dial, dual scale (psi and 2 kg/cm2), 2%-1%-2% accuracy.
Other gauges are available. See Gauge, Pressure, Test (High
Accuracy). For precision calibration of gauges see Dead Weight Tester . Other gauge testers are available for field calibration.
User Instructions |
RETURN |
Gauge, Pressure, Test (High Accuracy) |
Click on the picture for a larger view |
T-03-578 |
Gauge, mechanical, 60 psi, +/- 0.25 psi accuracy FS, 2-1/2"
dia. face |
T-03-715 |
100 psi, 0.5% accuracy FS, 3"
dia. face |
T-03-718 |
Gauge, digital, 100 psi, 0.1% accuracy FS, 2-1/2"
dia. face |
|
|
Special high accuracy gauges. See Gauge Tester, Bench, Dead Weight
for precision calibration of gauges. Other gauge testers are available,
T-03-578: mechanical, 60 psi in 0.5 psi increments with 2-1/2' diameter dial. No recalibration necessary. +/- 0.25% accuracy, full scale. 1/4" NPT lower connection.
T-03-715: 0-100 psi in 1/2 psi increments with 3" diameter dial, 1/4" MNPT connection, recalibration screw directly on the face of the dial, +/- .5% accuracy.
T-03-718: 0-100 psi in 0.1 psi increments with 2-1/2" diameter dial, 1/4" MNPT
connection, zero adjustment knob directly on the face of the dial, +/- 0.1 psi accuracy. |
RETURN |
Gauge, Vacuum, Electronic With Digital Meter |
Click on the picture for a larger view |
T-11-520 |
Unit, complete |
T-11-521 |
Digital vacuum meter, |
T-02-817 |
Electronic vacuum gauge, only |
|
|
The Terriss Digital Vacuum Meter comes complete with electronic vacuum gauge and a power cord. The vacuum meter can be calibrated to any physical standard.
Features:
• Quick disconnect permits the vacuum gauge to be removed without tools (1/8th MNPT is standard. Other sizes are available. Please specify.)
• Range: 0 to 30 inches of mercury
• Accuracy: +/- 0.25% of full scale
• Ruggedly constructed and water resistant
• RS232 port for connection to a computer
• 120 VAC is standard. 220 VAC is available. Please specify.
• Special rack mounting kits are available. Please inquire.
Terriss offers custom meters manufactured to your specifications. Please inquire. |
RETURN |
Gauge, Vacuum, Mechanical |
|
Many available. Please inquire. |
RETURN |
Gauge, Wall Thickness, Electronic |
Click on the picture for a larger view |
T-14-201 |
Model FH 4100 meter with probe |
T-14-205 |
Printer for wall thickness gauge |
T-14-208 |
AC adapter, 110 or 220 VAC |
|
|
Measure wall thickness of PET, glass and any other non-magnetic material. Slide the probe across the surface and the target ball will follow, showing the thickness at any point on a large digital display. The gauge can be connected to a PC or printer. Suitable for the laboratory or production.
Measuring Ranges and Accuracy:
• 0 - 2 mm with a steel ball (1.5 mm), +/- 5 microns + 1% of reading
• 0 - 4 mm with a steel ball (3.0 mm), +/- 10 microns + 1% of reading
• 0 - 8 mm with a steel ball (5.0 mm), +/- 20 microns + 1% of reading |
RETURN |
Glassware, Laboratory, Certified, Custom |
Click on the picture for a larger view |
Certified, high quality laboratory glassware, calibrated using standards of the U.S. National Institute of Science and Technology (NIST) to assure maximum accuracy.
Standard items include flasks, cylinders, pipets and burets, which may be seen under those catagories in our catalog. However, we can fabricate custom items to your specifications and/or assist you in designing special apparatus. Contact us with your requirements.
Certified items are individually documented.
In order to assist you we need the following information:
1. Type of item required (flask, cylinder, etc.)
2. Material of construction (regular or borosilicate glass, etc.)
3. Size and calibrations required (English, Metric or both)
4. Specifiy "to contain" or "to deliver"
5. Number of units to be purchased
Please don't hesitate to contact us if you have any questions. |
|
RETURN |
Glycerine, Food Grade |
|
T-03-703 |
Glycerine, Food Grade, 16 oz |
|
RETURN |
Graduate, Cone Shape, Pharmaceutical Type |
Click on the picture for a larger view |
T-09-222 |
1/2 oz, glass |
T-09-223 |
1 oz/25 ml, glass |
T-09-224 |
2 oz/50 ml, glass |
T-09-225 |
4 oz/100 ml, glass |
T-09-227 |
8 oz/250 ml, glass |
T-09-228 |
16 oz/500 ml, glass |
T-09-229 |
32 oz/1000 ml, glass |
T-09-230 |
2 oz/50 ml, plastic |
T-09-231 |
4 oz/120 ml, plastic |
T-09-232 |
8 oz/250 ml, plastic |
T-09-233 |
16 oz/500 ml, plastic |
T-09-234 |
32 oz/1000 ml, plastic |
|
|
|
RETURN |
Headspace Elimination, Cone Assembly |
Click on the picture for a larger view |
T-03-907 |
Unit, complete, for 202 can |
T-03-903 |
Unit, complete, for 206/207 can |
T-03-904 |
Unit, complete, for 209/211 can |
T-03-910 |
Replacement cone for 202 can |
T-03-905 |
Replacement cone for 206/207 can |
T-03-906 |
Replacement cone for 209/211 can |
|
|
Testing of air content in cans prior to closing is simplified by the use of a Headspace Elimination Cone. The cone is lowered into the can displacing the headspace air and excess product. Once tightened, the can is inverted and the air content can be tested with the Zahm New Style Air Tester. |
RETURN |
Hydrometer Rack |
Click on the picture for a larger view |
T-08-801 |
Hydrometer rack, 1" holes |
T-08-803 |
Hydrometer rack, 1 1/16" holes |
|
|
Protect and store your delicate glass hydrometers. Made of tough polypropylene. Compact, high capacity, holds 18 hydrometers. Measures 8-1/2" x 4-1/2" x 10" high. Holes accept most standard hydrometers. |
RETURN |
Hydrometer, Brewing, Balling, w/Thermometer, Certified |
T-08-713 |
Hydrometer, balling, 0 - 10 |
T-08-714 |
Hydrometer, balling, 10 - 20 |
T-08-715 |
Hydrometer, balling, 20 - 30 |
|
• Standardized at 60 deg. F.
• 0.1 divisions.
• Integral thermometer graduated 0 - 150 deg F.
• Without temperature correction scale.
• Certified and traceable to NIST standard. |
User Instructions |
RETURN |
Hydrometer, Brewing, Plato, w/Thermometer, Certified |
T-08-716 |
Hydrometer, plato, 0 - 8.5 |
T-08-717 |
Hydrometer, plato, 8 - 16.5 |
T-08-718 |
Hydrometer, plato, 16 - 24.5 |
T-08-719 |
Hydrometer, plato, 0 - 14 |
T-08-720 |
Hydrometer, plato, 0 - 24 |
|
• Standardized at 14 R.
• 0.1 divisions.
• Integral thermometer graduated from 0 - 35 Reaumer with temperature correction chart.
• Certified and traceable to NIST standards. |
User Instructions |
RETURN |
Hydrometer, Brewing, Proof, Tralles, w/Therm, Certified |
T-08-712 |
Hydrometer, 0 - 100 tralles and 0- 200 proof |
|
• Standardized at 60 deg. F.
• Integral 0 - 150 deg F thermometer.
• Without temperature correction scale.
• Certified and traceable to NIST standards. |
User Instructions |
RETURN |
Hydrometer, Brewing, Proof, without Thermometer, Certified |
T-08-701 |
Hydrometer, proof, 0 - 20 |
T-08-702 |
Hydrometer, proof, 20 - 40 |
T-08-703 |
Hydrometer, proof, 40 - 60 |
T-08-704 |
Hydrometer, proof, 60 - 80 |
T-08-705 |
Hydrometer, proof, 75 - 95 |
T-08-706 |
Hydrometer, proof, 90 - 110 |
T-08-707 |
Hydrometer, proof, 105 - 125 |
T-08-708 |
Hydrometer, proof, 125 - 145 |
T-08-709 |
Hydrometer, proof, 145 - 165 |
T-08-710 |
Hydrometer, proof, 165 - 185 |
T-08-711 |
Hydrometer, proof, 185 - 200 |
|
• Standardized at 60 Deg F
• 0.2% proof divisions.
• Certified and traceable to NIST standards. |
User Instructions |
RETURN |
Hydrometer, Fructose, Certified, 42% and 55%, w/Mercury Thermometer |
T-08-421 |
0 - 10 (42%) |
T-08-422 |
8 - 15 (42%) |
T-08-423 |
9 - 20 (42%) |
T-08-425 |
18 - 30 (42%) |
T-08-424 |
28 - 40 (42%) |
T-08-426 |
38 - 50 (42%) |
T-08-427 |
48 - 60 (42%) |
T-08-428 |
58 - 70 (42% |
Precision instruments for measuring percent of solids in liquid by weight. Choose scale for 42% or 55% fructose. Calibrated in 1/10th divisions and includes a built-in mercury thermometer and temperature correction scale.
|
User Instructions |
|
T-08-429 |
68 - 80 (42%) |
T-08-551 |
0 - 10 (55%) |
T-08-553 |
9 - 20 (55%) |
T-08-554 |
18 - 30 (55%) |
T-08-555 |
28 - 40 (55%) |
T-08-556 |
8 - 50 (55%) |
T-08-557 |
48 - 60 (55%) |
T-08-559 |
68 - 80 (55%) |
These hydrometers are tested and measured against reference hydrometers whose accuracy is traceable to the National Institute of Standards and Technology (NIST). Units are serially numbered with certificate enclosed. |
|
|
RETURN |
Hydrometer, Fructose, Certified, 42% and 55%,
w/Red Spirit Thermometer |
T-08-330 |
0 - 10 (42%) |
T-08-332 |
8 - 15 (42%) |
T-08-334 |
9 - 20 (42%) |
T-08-336 |
18 - 30 (42%) |
T-08-338 |
28 - 40 (42%) |
T-08-340 |
38 - 50 (42%) |
T-08-342 |
48 - 60 (42%) |
T-08-344 |
58 - 70 (42% |
T-08-346 |
68 - 80 (42%) |
|
T-08-331 |
0 - 10 (55%) |
T-08-333 |
8 - 15 (55%) |
T-08-335 |
9 - 20 (55%) |
T-08-337 |
18 - 30 (55%) |
T-08-339 |
28 - 40 (55%) |
T-08-341 |
38 - 50 (55%) |
T-08-343 |
48 - 60 (55%) |
T-08-345 |
58 - 70 (55%) |
T-08-347 |
68 - 80 (55%) |
|
Precision instruments for measuring percent of solids in liquid by weight. Choose scale for 42% or 55% fructose. Calibrated in 1/10th divisions and includes a built-in red spirit thermometer and temperature correction scale.
These hydrometers are tested and measured against reference hydrometers whose accuracy is traceable to the National Institute of Standards and Technology (NIST). Units are serially numbered with certificate enclosed. |
User Instructions |
RETURN |
Hydrometer, Sucrose, Certified, w/Mercury Thermometer |
T-08-101 |
0 - 5 brix |
T-08-102 |
3.5 - 6.5 brix |
T-08-103 |
5 - 15 brix |
T-08-104 |
8.5 - 14.5 brix |
T-08-105 |
9 - 21 brix |
T-08-106 |
20 - 30 brix |
T-08-107 |
25 - 36 brix |
T-08-108 |
30 - 40 brix |
T-08-109 |
40 - 50 brix |
|
T-08-110 |
50 - 60 brix |
T-08-111 |
52 - 58 brix |
T-08-112 |
53 - 65 brix |
T-08-113 |
60 - 70 brix |
T-08-114 |
70 - 80 brix |
T-08-115 |
20 - 30 baume |
T-08-116 |
25 - 30 baume |
T-08-117 |
28.5 - 35 baume |
T-08-118 |
35 - 39 baume |
|
All certified hydrometers are tested and measured against reference hydrometers whose accuracy is traceable to the National Institute of Standards and Technology. Accurate to 1/10 brix. Precision instruments with built-in mercury thermometers and temperature correction scales. Standardized at 20 deg C. Sucrose scale in 1/10 divisions. All are serially numbered with certificate enclosed.
Other ranges readily available to order. |
User Instructions |
RETURN |
Hydrometer, Sucrose, Certified, w/Red Spirit Thermometer |
T-08-301 |
0 - 5 brix |
T-08-302 |
3.5 - 6.5 brix |
T-08-303 |
5 - 15 brix |
T-08-304 |
8.5 - 14.5 brix |
T-08-306 |
9 - 21 brix |
T-08-307 |
20 - 30 brix |
T-08-308 |
25 - 36 brix |
T-08-309 |
30 - 40 brix |
T-08-310 |
40 - 50 brix |
|
T-08-311 |
50 - 60 brix |
T-08-312 |
52 - 58 brix |
T-08-313 |
53 - 65 brix |
T-08-314 |
60 - 70 brix |
T-08-315 |
70 - 80 brix |
T-08-316 |
20 - 30 baume |
T-08-317 |
25 - 30 baume |
T-08-318 |
28.5 - 35 baume |
T-08-319 |
35 - 39 baume |
|
|
All certified hydrometers are tested and measured against reference hydrometers whose accuracy is traceable to the National Institute of Standards and Technology. Accurate to 1/10 brix. Precision instruments with built-in red spirit thermometers and temperature correction scales. Standardized at 20 deg C. Sucrose scale in 1/10 divisions. All are serially numbered with certificate enclosed.
|
Other ranges readily available to order. |
|
User Instructions |
RETURN |
Hydrometer, Sucrose, Non-Certified, w/Mercury Thermometer |
T-08-201 |
8.5 - 14.5 brix |
T-08-202 |
30 - 40 brix |
T-08-203 |
52 - 58 brix |
|
T-08-204 |
25 - 30 baume |
T-08-205 |
28.5 - 35 baume |
T-08-206 |
35 - 39 baume |
|
|
Standardized temperature 20 deg C. Built-in mercury thermometer and temperature correction scale. Sucrose scale in 1/10 divisions. Other ranges available. Please inquire. |
User Instructions |
RETURN |
Hydrometer, Sucrose, Non-Certified, w/Red Spirit Thermometer |
T-08-321 |
8.5 - 14.5 brix |
T-08-322 |
30 - 40 brix |
T-08-323 |
52 - 58 brix |
|
T-08-324 |
25 - 30 baume |
T-08-325 |
28.5 - 35 baume |
T-08-326 |
35 - 39 baume |
|
Standardized temperature 20 deg C. Built-in red spirit thermometer and temperature correction scale. Sucrose scale in 1/10 divisions. Other ranges available. Please inquire. |
User Instructions |
RETURN |
Hydrometer, Sucrose, Royal Crown, Certified, w/Mercury Thermometer |
T-08-501 |
3.5 - 6.5 brix |
T-08-502 |
6 - 18 brix |
T-08-503 |
8.5 - 14.5 brix |
T-08-504 |
69 - 81 brix |
T-08-505 |
19 - 21 baume |
|
T-08-506 |
19 - 31 baume |
T-08-507 |
25 - 35 baume |
T-08-508 |
29 - 41 baume |
T-08-509 |
35 - 39 baume |
User Instructions |
|
Certified Hydrometers are tested and measured against reference hydrometers whose accuracy is traceable to the National Institute of Standards and Technology. Accurate to 1/10
brix. Precision instruments with built-in mercury thermometers and temperature correction scales. Sucrose scale in 1/10 divisions. Standardized temperature 60 deg F. Serially numbered with certificate enclosed.
|
Other ranges readily available. Please inquire |
|
User Instructions |
RETURN |
Hydrometer, Sucrose, Royal Crown, Certified, w/Red Spirit Thermometer |
T-08-350 |
3.5 - 6.5 brix |
T-08-351 |
6 - 18 brix |
T-08-352 |
8.5 - 14.5 brix |
T-08-353 |
69 - 81 brix |
T-08-354 |
9 - 21 baume |
|
T-08-355 |
9 - 31 baume |
T-08-356 |
25 - 35 baume |
T-08-357 |
29 - 41 baume |
T-08-358 |
35 - 39 baume |
|
Certified Hydrometers are tested and measured against reference hydrometers whose accuracy is traceable to the National Institute of Standards and Technology. Accurate to 1/10 brix. Precision instruments with built-in red spirit thermometers and temperature correction scales. Sucrose scale in 1/10 divisions. Standardized temperature 60 deg F. Serially numbered with certificate enclosed.
Other ranges readily available. Please inquire. |
User Instructions |
RETURN |
Hydrometer, Sucrose, Royal Crown, Non-Certified, w/Mercury Thermometer |
T-08-601 |
3.5 - 6.5 brix |
T-08-602 |
6 - 18 brix |
T-08-603 |
8.5 - 14.5 brix |
T-08-604 |
69 - 81 brix |
|
T-08-605 |
9 - 21 baume |
T-08-606 |
19 - 31 brix |
T-08-607 |
25 - 35 brix |
T-08-608 |
35 - 39 brix |
|
Standardized at 60 deg F. Built-in mercury thermometers with temperature correction scale. Sucrose scale is in 1/10 divisions. Other ranges are available. Please inquire. |
User Instructions |
RETURN |
Hydrometer, Sucrose, Royal Crown, Non-Certified, w/Red Spirit Thermometer |
T-08-361 |
3.5 - 6.5 brix |
T-08-362 |
6 - 18 brix |
T-08-363 |
8.5 - 14.5 brix |
T-08-364 |
69 - 81 brix |
|
T-08-365 |
9 - 21 baume |
T-08-366 |
19 - 31 brix |
T-08-367 |
25 - 35 brix |
T-08-368 |
35 - 39 brix |
|
Standardized at 60 deg F. Built-in red spirit thermometers with temperature correction scale. Sucrose scale is in 1/10 divisions. Other ranges are available. Please inquire. |
User Instructions |
|
|